Comments received on Draft 2.1 and comments carried over from Draft 2.0 IEEE P802.3aq Draft 2.1 Comments # 1001Cl 00 SC P L Comment Type TR See John George's Comment #6 in recirculation package. Sugge
IEEE P802.3ck D2.0 100/200/400 Gb/s Electrical Interfaces Task Force Initial Working Group ballot comments # 229Cl FM SC FM P 1 L 10 Comment Type E From the amendment list starting at line 28, it appe
IEEE P802.3df D1.0 1st Task Force review comments Proposed Response # 1Cl 45 SC 45.2.4 P 47 L 4 Comment Type T "45.2.4 PHY XS registers" and "45.2.5 DTE XS registers" subsections need to be brought in
IEEE P802.3df D1.0 1st Task Force review comments Proposed Response # 1Cl 45 SC 45.2.4 P 47 L 4 Comment Type T "45.2.4 PHY XS registers" and "45.2.5 DTE XS registers" subsections need to be brought in
IEEE P802.3df D1.0 1st Task Force review comments # 110Cl FM SC FM P 1 L 10 Comment Type E "Amendment:" - there should be an amendment number here. According to pages 13 and 14, this would be number 1
IEEE P802.3df D1.0 1st Task Force review comments # 110Cl FM SC FM P 1 L 10 Comment Type E "Amendment:" - there should be an amendment number here. According to pages 13 and 14, this would be number 1
MainTable IEEE P802.3cp D2.0 Bidirectional 10 Gb/s, 25 Gb/s, and 50 Gb/s Optical Access PHYs Initial Working Group ballot comments # 147Cl FM SC FM P1 L10 Comment Type ER State this is amendment 11 an
IEEE P802.3ck D2.0 100/200/400 Gb/s Electrical Interfaces Task Force Initial Working Group ballot comments Proposed Response # 1Cl 45 SC 45.2.1.115a P 46 L 13 Comment Type E When a new subclause is in
MainTable IEEE P802.3bj D3.0 100 Gb/s Backplane and Copper Cable Initial Sponsor ballot comments # i-6Cl 00 SC 0 P L Comment Type G General comment SuggestedRemedy There appears to be editorial opport
MainTable IEEE P802.3ba D3.0 40Gb/s and 100Gb/s Ethernet comments Draft 3.0 Comments Sponsor ballot # 611Cl 00 SC 0 P L Comment Type ER Global - Plots of insertion loss, return loss, crosstalk limits
Comment ID Date Comment . Name Email Phone Style Index . Classification Vote Category Page Subclause Line Comment File Must Be Satisfied Proposed Change Resolution Status Resolution Detail Other1 Othe
IEEE P802.3df D1.1 2nd Task Force review comments # 47Cl FM SC FM P 1 L 31 Comment Type E "adds MAC parameters, Physical Layers, and management parameters" but we talk about "the Physical Layer" like
IEEE 802.17 Terms and Definitions Proposed Comment Resolutions Sorted by Comment ID # 1Cl 01 SC 01.39 P 3 L Comment Type E I think it is confusing SuggestedRemedy It should read ..at the destination s
MainTable IEEE P802.3 (IEEE 802.3dc) D3.0 Maintenance #16 (Revision) Initial Sponsor ballot comments # I-43Cl FM SC FM P 1 L26 Comment Type E Don't forget to update copyright year here and next page,
IEEE 802.3by D2.1 25 Gb/s Ethernet 1st Working Group recirculation ballot comments # 88Cl FM SC FM P 11 L 17 Comment Type E One would reasonably assume that "the existing base standard and its amendme
IEEE P802.3cg D3.0 Physical Layer Specifications and Management Parameters for 10 Mb/s Operation and Associated Power Delivery over a Single Balanced Pair of Conductors Initial Sponsor ballot comments
Approved meeting minutes - May 2023 Joint Meeting of the IEEE P802.3cw DWDM Systems Task Force, IEEE P802.3df 400 Gb/s and 800 Gb/s Ethernet Task Force and IEEE P802.3dj 200 Gb/s, 400 Gb/s, 800 Gb/s,
Microsoft Word - MagnumOpus-final draft-10.doc 2/12/2004: 3:21 PM Big Broadband thru Open AFNs 1 The Case for Deploying “Big Broadband” Through Open Advanced Fiber Networks (AFNs) Executive Summary Th
IEEE P802.3cy D3.0 10G+ Auto Task Force Initial Sponsor ballot commentsApproved Responses # I-14Cl FM SC FM P 1 L 10 Comment Type E It appears to me that this project is likely to get to RevCom before
Microsoft Word - 802161pc-00_02.doc 1999-12-24 IEEE 802.16.1pc-00/02 Project IEEE 802.16 Broadband Wireless Access Working Group Title Physical Layer Proposal for the 802.16 Air Interface Specificatio
IEEE P802.3bq D2.1 Physical Layer and Management Parameters for 40Gb/s Operation, Type 40GBASE-T 1st Working Group recirculation ballot comments Response # 1Cl 113 SC 113.3.6.4 P 117 L 37 Comment Type
IEEE P802.3bq D2.1 Physical Layer and Management Parameters for 40Gb/s Operation, Type 40GBASE-T 1st Working Group recirculation ballot comments # 119Cl 00 SC 0 P L Comment Type TR Motion 32 at the 80