MainTable D2.1 Physical Layer Specifications and Management Parameters for 2.5 Gb/s, 5 Gb/s, and 10 Gb/s Autom P802.3ch D2.1 168Cl 149 SC 149.4.2.4.5 P L Comment Type E SuggestedRemedy REJECT. empty c
IEEE 802.3by D1.0 25 Gb/s Ethernet 2nd Task Force review comments Proposed Response # 1Cl 045 SC 45.2.1.102.1 P 43 L 16 Comment Type E "alignment markers lock" should be "alignment marker lock" Sugges
IEEE P802.3bq D3.0 25G/40GBASE-T Ethernet Initial Sponsor ballot comments i-97Cl 113 SC 113.11 P 196 L 27 Comment Type TR Equation 44-1 and Table 44-3 are specific to 10 Gb/s. For higher bit rates, th
IEEE 802.3by D1.0 25 Gb/s Ethernet 2nd Task Force review comments # 66Cl 000 SC 0 P L Comment Type E The PDF Document Properties are not filled in completely: Title: IEEE P802.3xx name of Task Force S
MainTable D2.1 Physical Layer Specifications and Management Parameters for 2.5 Gb/s, 5 Gb/s, and 10 Gb/s Autom P802.3ch D2.1 Proposed Response # 1Cl 45 SC 45.2.1 P 32 L 31 Comment Type T The definitio
1 | P a g e MINUTES (Unconfirmed) IEEE 802 LMSC EXECUTIVE COMMITTEE MEETING, Revision 1 Prepared by John D’Ambrosia, Recording Secretary Monday, March 9, 2015 – 8:00 a.m. All times CET Estrel Berlin B
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
IEEE 802.3by D1.0 25 Gb/s Ethernet 2nd Task Force review comments Response # 1Cl 045 SC 45.2.1.102.1 P 43 L 16 Comment Type E "alignment markers lock" should be "alignment marker lock" SuggestedRemedy
IEEE P802.3bq D3.0 25G/40GBASE-T Ethernet Initial Sponsor ballot comments # i-89Cl 0 SC 0 P L Comment Type TR The style manual says "...the use of the word must is deprecated and shall not be used whe
IEEE 802.3by D1.0 25 Gb/s Ethernet 2nd Task Force review comments # 66Cl 000 SC 0 P L Comment Type E The PDF Document Properties are not filled in completely: Title: IEEE P802.3xx name of Task Force S
MainTable IEEE P802.3at D3.0 PoEplus comments Response # 1Cl 33E SC 33E P 151 L 10 Comment Type E Include a reference to channel DC resistance unbalance specifications defined by TIA. SuggestedRemedy
MainTable IEEE P802.3at D3.0 PoEplus comments # 467Cl 00 SC 00 P L Comment Type ER The current ballot claims that it is referenced against P802.3ay Draft 2.1. As of the date of the close of this ballo
MainTable IEEE P802.3at D4.0 PoEplus comments # 178Cl 00 SC 0 P L Comment Type GR The impulse value of 1.5 kV 10/700 is too low for the above reasons. Compliance only to the lower 1.5 kV 10/700 condit
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments # 581Cl 120A SC 120A.6 P 103 L 43 Comment Type E two 400GMII and 400GAUI-8 interfaces SuggestedRemedy Only
MainTable IEEE P802.3at D4.0 PoEplus comments Response # 1Cl 25 SC 25.4.4a.1 P 19 L 51 Comment Type G Draft D4 Figure 25-1 title: The title use "test fixture" and the text in Note 1 use "test circuit"
MainTable IEEE P802.3bj D1.3 100 Gb/s Backplane and Copper Cable 4th Task Force review comments Proposed Response # 1Cl 91 SC 91.5.4.2.1 P 145 L 49 Comment Type E Missing word? "received on at 2 PCS l
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable P802.3z Draft 4 Comments # 210Cl 00 SC 00.iv P iv L 24 Comment Type E Symbol for Boolean XOR is listed as ( )̂. This conflicts with the symbol given in 802.3x/802.3y documents, which is a pl
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3bj D1.3 100 Gb/s Backplane and Copper Cable 4th Task Force review comments # 67Cl 00 SC 0 P L Comment Type E Some hyperlinks to Figures and Tables within the document do not work.