MainTable IEEE P802.3at D3.0 PoEplus comments Response # 1Cl 33E SC 33E P 151 L 10 Comment Type E Include a reference to channel DC resistance unbalance specifications defined by TIA. SuggestedRemedy
MainTable IEEE P802.3at D3.0 PoEplus comments # 467Cl 00 SC 00 P L Comment Type ER The current ballot claims that it is referenced against P802.3ay Draft 2.1. As of the date of the close of this ballo
MainTable IEEE P802.3at D4.0 PoEplus comments # 178Cl 00 SC 0 P L Comment Type GR The impulse value of 1.5 kV 10/700 is too low for the above reasons. Compliance only to the lower 1.5 kV 10/700 condit
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments # 581Cl 120A SC 120A.6 P 103 L 43 Comment Type E two 400GMII and 400GAUI-8 interfaces SuggestedRemedy Only
MainTable IEEE P802.3at D4.0 PoEplus comments Response # 1Cl 25 SC 25.4.4a.1 P 19 L 51 Comment Type G Draft D4 Figure 25-1 title: The title use "test fixture" and the text in Note 1 use "test circuit"
MainTable IEEE P802.3bj D1.3 100 Gb/s Backplane and Copper Cable 4th Task Force review comments Proposed Response # 1Cl 91 SC 91.5.4.2.1 P 145 L 49 Comment Type E Missing word? "received on at 2 PCS l
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments Response # 1Cl 00 SC 0 P 12 L 47 Comment Type E If you look at the 802.3cy project, it states th
MainTable P802.3z Draft 4 Comments # 210Cl 00 SC 00.iv P iv L 24 Comment Type E Symbol for Boolean XOR is listed as ( )̂. This conflicts with the symbol given in 802.3x/802.3y documents, which is a pl
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3cw D2.1 400 Gb/s over DWDM systems 1st Working Group recirculation ballot comments # 231Cl FM SC FM P 10 L 16 Comment Type E "physical layer" should be capitalized SuggestedRemedy
MainTable IEEE P802.3bj D1.3 100 Gb/s Backplane and Copper Cable 4th Task Force review comments # 67Cl 00 SC 0 P L Comment Type E Some hyperlinks to Figures and Tables within the document do not work.
IEEE P802.3cd 50 Gb/s, 100 Gb/s, 200 Gb/s Ethernet 1st Task Force review comments # 69Cl FM SC FM P 15 L 2 Comment Type E In the table of contents, there is no space between clause number and clause t
IEEE P802.3bq D2.1 Physical Layer and Management Parameters for 40Gb/s Operation, Type 40GBASE-T 1st Working Group recirculation ballot comments Proposed Response # 1Cl 113 SC 113.3.6.4 P 117 L 37 Com
MainTable IEEE P802.3az D2.2 Energy Efficient Ethernet commentsProposed responses Jan 2010 Proposed Response # 1Cl 36 SC 36.2.5.2.2 P 83 L 13 Comment Type TR Branches from LPI_IDLE_D, LPI_K, RX_WAKE,
802.3ae IEEE P802.3ba D1.2 40Gb/s and 100Gb/s Ethernet comments Draft 1.2 Comments Task force Review Proposed Response # 1Cl 82 SC 82.2.4.4 P 170 L 15 Comment Type T 'TXC or RXC' is not specified for
IEEE P802.3df D1.0 1st Task Force review comments # 110Cl FM SC FM P 1 L 10 Comment Type E "Amendment:" - there should be an amendment number here. According to pages 13 and 14, this would be number 1
IEEE P802.3bq D2.1 Physical Layer and Management Parameters for 40Gb/s Operation, Type 40GBASE-T 1st Working Group recirculation ballot comments # 119Cl 00 SC 0 P L Comment Type TR Motion 32 at the 80
IEEE P802.3ae/D4.3 comment responses P802.3ae Draft 4.3 Comments # 71Cl 00 SC 52 P 481 L 12 Comment Type E This is a resubmission and update of a comment I made on D4.2 which was overlooked. Why are F
[STDS-802-11-TGM] Current status of TGmc comments and assignees Thread Links Date Links Thread Prev Thread Next Thread Index Date Prev Date Next Date Index [STDS-802-11-TGM] Current status of TGmc com