119116 results found. results are sorted by relevance
  201-225
https://grouper.ieee.org/groups/802/16/tg2/contrib/C802162a-02_36.pdf
Coexistence Recommended Practice - working document version 1.5 2002-07-01 IEEE C802.16.2a-02/36 0 Project IEEE 802.16 Broadband Wireless Access Working Group Title Coexistence
https://grouper.ieee.org/groups/802/3/bj/comments/P8023bj-D1p1-Comments_Proposed_byCls_r1.pdf
MainTable IEEE P802.3bj D1.1 100 Gb/s Backplane and Copper Cable 2nd Task Force review comments # 172Cl 00 SC 0 P L Comment Type E Now that IEEE Std 802.3-2012 has been approved, update all references
https://grouper.ieee.org/groups/802/3/av/public/2008_09/3av_0809_comments_d2_0_received.pdf
MainTable IEEE 802.3av d2.0 10G-EPON comments IEEE 802.3av Draft 2.0 Comments Received # 2379Cl 00 SC P L Comment Type T This is the only use of the term 'PON Plant' - the term used elsewhere in the d
https://grouper.ieee.org/groups/802/16/tg2/docs/802162a-02_10.pdf
Coexistence Recommended Practice – draft amendment version 1 2002-07-11 IEEE 802.16.2a-02/10 0 Project IEEE 802.16 Broadband Wireless Access Working Group Title Coexistence Rec
https://grouper.ieee.org/groups/802/3/bj/comments/P8023bj-D1p1-Comments_Final_byID.pdf
MainTable IEEE P802.3bj D1.1 100 Gb/s Backplane and Copper Cable 2nd Task Force review comments Response # 1Cl 45 SC 45.2.7.14 P 25 L 32 Comment Type E Typo 10G instead of 100G in Table 45-191 Suggest
https://grouper.ieee.org/groups/802/3/bj/comments/P8023bj-D1p1-Comments_Proposed_byID_r1.pdf
MainTable IEEE P802.3bj D1.1 100 Gb/s Backplane and Copper Cable 2nd Task Force review comments Proposed Response # 1Cl 45 SC 45.2.7.14 P 25 L 32 Comment Type E Typo 10G instead of 100G in Table 45-19
https://grouper.ieee.org/groups/802/3/bj/comments/P8023bj-D1p1-Comments_Final_byCls.pdf
MainTable IEEE P802.3bj D1.1 100 Gb/s Backplane and Copper Cable 2nd Task Force review comments # 180Cl 00 SC 0 P L Comment Type T The content of the P802.3bj draft seems to be sufficiently stable tha
https://grouper.ieee.org/groups/802/3/ck/comments/draft2p0/8023ck_D2p0_final_closedcomments_sortedByNumber.pdf
IEEE P802.3ck D2.0 100/200/400 Gb/s Electrical Interfaces Task Force Initial Working Group ballot comments Response # 1Cl 45 SC 45.2.1.115a P 46 L 13 Comment Type E When a new subclause is inserted be
https://grouper.ieee.org/groups/802/3/az/comments/proposed802p3azd3p0-2.pdf
8023azD3p0proposedresponses-2 IEEE P802.3az D3.0 Energy Efficient Ethernet commentsProposed responses Proposed Response # 1Cl 55 SC 55.4.6.5 P 217 L 34 Comment Type E Comment 9 against D 2.3 was not f
https://grouper.ieee.org/groups/802/3/cd/comments/8023cd_D11_final_comment_responses_by_id.pdf
IEEE P802.3cd 50 Gb/s, 100 Gb/s, 200 Gb/s Ethernet 2nd Task Force review comments Response # 1Cl 045 SC 45.2.1.124 P 63 L 41 Comment Type T Remove editors note SuggestedRemedy Add 50G, 100G PAM4 to 45
https://grouper.ieee.org/groups/802/3/az/comments/proposed802p3azd3p0.pdf
8023azD3p0proposedresponses IEEE P802.3az D3.0 Energy Efficient Ethernet commentsProposed responses # 327Cl 00 SC 0 P L Comment Type ER Bookmark for 40.5.1 is under 40.4 SuggestedRemedy Correct bookma
https://grouper.ieee.org/groups/802/3/cd/comments/8023cd_D11_final_comment_responses_by_clause.pdf
IEEE P802.3cd 50 Gb/s, 100 Gb/s, 200 Gb/s Ethernet 2nd Task Force review comments # 93Cl 000 SC 0 P 0 L 0 Comment Type T PICS in Annexes 135B to 135G and 136B are incomplete. SuggestedRemedy Complete
https://grouper.ieee.org/groups/802/3/cd/comments/8023cd_D11_comment_proposed_responses_by_clause-v2.pdf
IEEE P802.3cd 50 Gb/s, 100 Gb/s, 200 Gb/s Ethernet 2nd Task Force review comments # 93Cl 000 SC 0 P 0 L 0 Comment Type T PICS in Annexes 135B to 135G and 136B are incomplete. SuggestedRemedy Complete
https://grouper.ieee.org/groups/802/3/cd/comments/8023cd_D11_comment_proposed_responses_by_ID-v2.pdf
IEEE P802.3cd 50 Gb/s, 100 Gb/s, 200 Gb/s Ethernet 2nd Task Force review comments Proposed Response # 1Cl 045 SC 45.2.1.124 P 63 L 41 Comment Type T Remove editors note SuggestedRemedy Add 50G, 100G P
https://grouper.ieee.org/groups/802/3/ck/comments/draft2p0/8023ck_D2p0_final_closedcomments.pdf
IEEE P802.3ck D2.0 100/200/400 Gb/s Electrical Interfaces Task Force Initial Working Group ballot comments # 229Cl FM SC FM P 1 L 10 Comment Type E From the amendment list starting at line 28, it appe
https://grouper.ieee.org/groups/802/3/bt/comments/802d3bt_D3p0_Incoming_CommentID.pdf
IEEE P802.3bt D3.0 4-Pair PoE Initial Sponsor ballot comments Proposed Response # i-1Cl 145 SC 145 P 142 L 10 Comment Type TR The IEEE-SA Standards Style Manual 13.3.2 says "An em dash (--) should be
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Oct_18_by_clause.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments # 151Cl FM SC FM P 1 L 2 Comment Type E IEEE Std 802.3-2022 is both approved and published. SuggestedRemed
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Sept_29_by_ID.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments Proposed Response # 1Cl FM SC FM P 1 L 25 Comment Type E "IEEE Std 802.3-202x" is no lomnger correct - we
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Sept_15_by_clause.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments # 151Cl FM SC FM P 1 L 2 Comment Type E IEEE Std 802.3-2022 is both approved and published. SuggestedRemed
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Sept_29_by_clause.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments # 151Cl FM SC FM P 1 L 2 Comment Type E IEEE Std 802.3-2022 is both approved and published. SuggestedRemed
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Oct_18_by_ID.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments Response # 1Cl FM SC FM P 1 L 25 Comment Type E "IEEE Std 802.3-202x" is no lomnger correct - we know it w
https://grouper.ieee.org/groups/802/3/efm/public/comments/d3_1/D3_1_prelim_report.pdf
MainTable P802.3ah Draft 3.1 Comments # 99300Cl 00 SC P L Comment Type TR The entirely new concept to 802.3 of doing shared access via an entirely new access protocol is hidden through lack of use of
https://grouper.ieee.org/groups/802/3/bt/comments/802d3bt_D3p0_Incoming_DraftOrder.pdf
IEEE P802.3bt D3.0 4-Pair PoE Initial Sponsor ballot comments i-476Cl 30 SC 30 P L Comment Type T Who is generating the SNMP MIBs based on clause 30? SuggestedRemedy Group to discuss. Comment Status X
https://grouper.ieee.org/groups/802/3/cw/comments/D2p0/8023cw_D2p0_comments_final_so_far_Sept_15_by_ID.pdf
MainTable IEEE P802.3cw D2.0 400 Gb/s over DWDM systems Initial Working Group ballot comments Proposed Response # 1Cl FM SC FM P 1 L 25 Comment Type E "IEEE Std 802.3-202x" is no lomnger correct - we
https://grouper.ieee.org/groups/802/3/at/comments/D3.0/P802d3at_D3p0_postmtg_closed_by_clause.pdf
MainTable IEEE P802.3at D3.0 PoEplus comments # 504Cl 00 SC 00 P L Comment Type TR Please resolve where the TLVs for 802.3at will reside. Will it be in 802.1, 802.3 at or somewhere else SuggestedRemed